SurgRx
🟡 Urgent
⚕️ Procedures

Continuous Bladder Irrigation (CBI) — Setup & Management

Continuous instillation of normal saline through a 3-way Foley catheter to prevent clot formation and wash blood from the bladder — the cornerstone management for gross hematuria with clot risk.

Setting up CBI post-TURBT, for gross hematuria with clots, or troubleshooting CBI not functioning (blocked outflow, bladder distension, inadequate clearing).

CWW Ch. 11 — Evaluation and Management of Hematuria

Top red flag

Patient in pain with CBI in place and no urine output → likely blocked catheter → manual irrigation immediately

First move

CBI SETUP:

Must not miss

Blocked CBI outflow causing bladder over-distension (dangerous — can cause bladder rupture or severe patient distress)

Quick consult script

Opening

“Hi, nursing called about a CBI issue — the output is [dark red / stopped] and the patient has suprapubic pain.”

Findings

“Patient is [X] hours post-TURBT. CBI running at [rate] mL/hr. Output is [character]. Input vs output ratio [approximately equal / output much less than input]. Manual irrigation attempted: [result].”

Assessment

“[Blocked CBI — clots obstructing outflow → manual irrigation + catheter change] / [Arterial bleeding not controlled by CBI → OR consideration].”

Plan

“[Blocked]: Manual irrigation performed. [If fails]: Changing to 24 Fr catheter. [If arterial]: Calling senior for return to OR.”

Call senior if…

  • Arterial bleeding not controlled by CBI
  • TURP syndrome (hyponatremia, confusion)
  • Catheter cannot be unblocked — OR for clot evacuation

  • Patient in pain with CBI in place and no urine output → likely blocked catheter → manual irrigation immediately
  • Continuous dark red output despite high CBI rate → significant arterial bleeding → OR for hemostasis
  • Confusion, hyponatremia, bradycardia → hypo-osmolar absorption (TURP syndrome) → stop CBI, serum sodium stat
  • Output much less than input (accounting for urine production) → catheter blocked or kinked

Must not miss

  • Blocked CBI outflow causing bladder over-distension (dangerous — can cause bladder rupture or severe patient distress)
  • Fluid absorption in TURBT-related CBI (TURP syndrome analog — rare but watch sodium)
  • Infection from non-sterile irrigation fluid (always use NS, not D5W — hemolysis risk)

Senior escalation triggers

  • Arterial bleeding uncontrolled by CBI → OR for hemostasis
  • Bladder distension from blocked CBI causing patient distress → manual irrigation + catheter change immediately
  • Hyponatremia during CBI post-TURBT (TURP syndrome) → call senior + nephrology

  • Hemoglobin: monitor for significant blood loss requiring transfusion
  • BMP: sodium (TURP syndrome screen), creatinine
  • Strict input/output: CBI input must approximately equal output (+ estimated urine production)

Imaging tips

  • Bladder US: if CBI blocked and manual irrigation fails — confirms clot burden and guides decision for OR clot evacuation

  • CBI SETUP:
  • 1. Use 22-24 Fr 3-way Foley catheter (essential — allows simultaneous inflow and outflow)
  • 2. Connect 3L bags of normal saline (NOT sterile water or D5W) to the irrigation (inflow) port
  • 3. Connect drainage bag to the outflow (Foley drainage) port
  • 4. Start rate: 500-1000 mL/hr initially; titrate to keep output clear to pink
  • 5. Monitor output color continuously; increase rate if dark; decrease if clear × 4 hours
  • CBI TROUBLESHOOTING:
  • Blocked outflow:
  • 1. Check for kinks in tubing
  • 2. Manual irrigation: 60 mL piston syringe, NS; aspirate clots
  • 3. If clots removed → resume CBI
  • 4. If cannot irrigate → change catheter (larger size, 24 Fr)
  • Dark red output despite max CBI rate:
  • → Arterial bleeding; call senior; consider OR for fulguration/hemostasis
  • Output much less than input:
  • → Blocked → irrigate manually; catheter change if fails
  • Hyponatremia / confusion:
  • → Stop CBI; check serum Na; TURP syndrome (rare with modern monopolar resectoscopes using glycine — bipolar uses saline so lower risk)
  • CBI DISCONTINUATION:
  • Urine output remains pink to yellow × 4-6 hours at low rate (200-300 mL/hr) → discontinue CBI
  • Switch to standard 2-way Foley → monitor for re-bleeding

Antibiotics

  • Post-TURBT: prophylactic antibiotics per pre-operative plan
  • If CBI-related infection suspected: urine culture + appropriate antibiotics

Catheter considerations

  • 3-way catheter anatomy: Port 1 = balloon inflation; Port 2 = irrigation inflow; Port 3 = urine outflow
  • The inflow port MUST be connected to saline bags; the outflow port to drainage bag — swapping them blocks drainage
  • Manual irrigation technique: pull back plunger to aspirate clots before pushing saline in; never force if resistance
  • Input-output tracking: essential to catch blocked catheter early

Search keywords

CBI · continuous bladder irrigation · 3-way Foley · bladder irrigation · post-TURBT CBI · hematuria CBI · bladder clot irrigation